with Swiss Power Connector SEV1011 Typ13 OR Schuko available
The EMI-LISN50UH is the TEKBOX TBLC08 50μH Line Impedance Stabilization Network (LISN) for the measurement of line-conducted interference within the range of 9 kHz to 30 MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 260 V. Conducted noise can be measured on the phase and on the neutral conductor. The TBLC08 is equipped with a switchable limiter/attenuator and an artificial hand connection. Three models are available with country-specific DUT connectors.
Key features
- Frequency range: 9 kHz to 30 MHz
- Impedance: 50 Ω ‖ (50 μH + 5 Ω)
- Artificial hand: 220 pF + 511 Ω
- Switchable PE: 50 Ω ‖ 50 μH
- Limiter / attenuator: 150 kHz to 30 MHz; 10 dB
- Air core inductors
- Line voltage: max. 240V / 50 – 60 Hz, CAT ‖
- Max. current: 8A @ 23°C
- DUT socket: country specific
- Measurement connector: 50 Ω BNC
- Power connector: SEV1011 Typ13
- Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH
- Safety Class I, IEC 1010-01
Applications
- EMC pre-compliance testing of conducted noise